High-voltage-resistant conductor for all classes of lightning protection systems (LPS)
HVI®power Conductor
Different models and their specifications
High-voltage-resistant, insulated down conductor for maintaining the separation distance to electrically conductive parts according to IEC/EN 62305-3.
-
Technical specifications (819 160)
HVI®power Conductor (pre-assembled, installation inside the tube) Type HVI P RIV 90 27 L6M SW Part No. 819 160 Material of conductor Cu Material of insulation PE Material of sheath PE Color of conductor black ● RAL color similar to 9011 Cross section of core 25 mm² Lightning current carrying capability (class / Iimp) H2 / 200 kA Equivalent separation distance s (in air) ≤ 90 cm Diameter Ø conductor 27 mm Characteristics of sheath UV stabilised and weather resistant Minimum order length 6 m Maximum order length 35 m Standard DIN IEC/TS 62561-8 (VDE V 0185-561-8) Weight 4,8 kg GTIN 4013364152298 PU 1 pc(s)
Downloads for 819 160
HVI P RIV 90 27 L6M SW
HVI®power Conductor (pre-assembled, installation inside the tube)
-
Technical specifications (819 165)
HVI®power Conductor (pre-assembled, installation outside the tube) for HVI power supporting tube GRP / Al Type HVI P RAV 90 27 L6M SW Part No. 819 165 Material of conductor Cu Material of insulation PE Material of sheath PE Color of conductor black ● RAL color similar to 9011 Cross section of core 25 mm² Lightning current carrying capability (class / Iimp) H2 / 200 kA Equivalent separation distance s (in air) ≤ 90 cm Diameter Ø conductor 27 mm Characteristics of sheath UV stabilised and weather resistant Minimum order length 6 m Maximum order length 35 m Standard DIN IEC/TS 62561-8 (VDE V 0185-561-8) Weight 4,48 kg GTIN 4013364272224 PU 1 pc(s)
Downloads for 819 165
HVI P RAV 90 27 L6M SW
HVI®power Conductor (pre-assembled, installation outside the tube) for HVI power supporting tube GRP / Al
-
Technical specifications (819 137)
HVI®power long Conductor (on a reel) Type HVI P LO 90 27 L100M SW Part No. 819 137 Material of conductor Cu Material of insulation PE Material of sheath PE Color of conductor black ● RAL color similar to 9011 Cross section of core 25 mm² Lightning current carrying capability (class / Iimp) H2 / 200 kA Equivalent separation distance s (in air) ≤ 90 cm Diameter Ø conductor 27 mm Characteristics of sheath UV stabilised and weather resistant Minimum order length 6 m Maximum order length 35 m Standard DIN IEC/TS 62561-8 (VDE V 0185-561-8) Weight 854 g/m GTIN 4013364152625 PU 100 m
Downloads for 819 137
HVI P LO 90 27 L100M SW
HVI®power long Conductor (on a reel)
-
Technical specifications (819 163 & 819 161)
HVI®power long Conductor (cut to length) Type HVI P LO 90 27 L6...35M SW HVI P LO 90 27 L6...35M SW Part No. 819 163 819 161 Material of conductor Cu Cu Material of insulation PE PE Material of sheath PE PE Color of conductor black ● black ● RAL color similar to 9011 similar to 9011 Cross section of core 25 mm² 25 mm² Lightning current carrying capability (class / Iimp) H2 / 200 kA H2 / 200 kA Equivalent separation distance s (in air) ≤ 90 cm ≤ 90 cm Diameter Ø conductor 27 mm 27 mm Characteristics of sheath UV stabilised and weather resistant UV stabilised and weather resistant Minimum order length 6 m 36 m Maximum order length 35 m 80 m Standard DIN IEC/TS 62561-8 (VDE V 0185-561-8) DIN IEC/TS 62561-8 (VDE V 0185-561-8) Weight 4,36 kg 25,97 kg GTIN 4013364280199 4013364281646 PU 1 pc(s) 1 pc(s)
Downloads for 819 163 & 819 161
HVI P LO 90 27 L36...80M SW
HVI®power long Conductor (cut to length)